In brief
MSC.1/Circ.1615 is the interim guidance IMO issued after a series of ro-pax vehicle-deck fires. It came out of the EMSA-commissioned FIRESAFE studies and covers the whole fire chain: prevention, detection and decision, extinguishment, containment and evacuation.
It is recommendatory. Most of its detection and decision measures for ro-pax ships became mandatory on 1 January 2026 through MSC.550(108) and MSC.555(108): weather-deck detection, video monitoring, sectioned alarms, alarm presentation and drencher signage.
Who it applies to
- Ro-ro spaces and special category spaces of new and existing ro-ro passenger ships.
- Section 1 (prevention) applies to new and existing ships; sections 2 to 5, except 3.2, apply to new ships unless stated otherwise. Recommendatory, not mandatory.
What it requires
- 1.1–1.6
- Electrical supply to vehicles and cargo units
Inspect ship power cables and sockets before use, use only ship-supplied cables, protect cables from loading damage, sockets of at least IP56, detect detrimental loads and earth faults, and connect or disconnect only by trained personnel.
- 1.7
- Fire patrols
Patrols check for vehicle leaks and the condition of electrical connections; portable thermal imaging devices are recommended for screening during rounds.
- 1.8
- Alternatively powered vehicles
A fire-fighting plan that identifies risks specific to battery-powered and other alternatively powered vehicles, with training and access to specialised equipment; attention to lighter-than-air gases collecting under ceilings.
- 2.1–2.4
- Detection
Individually addressable detectors recommended for ships built before July 2010; detection sections matching deluge sections; video monitoring with immediate playback; smoke detection in open ro-ro spaces supplemented by flame or heat detectors; fixed detection on weather decks.
- 2.5–2.6
- Alarms and signage
A consistent alarm presentation scheme on the bridge and photoluminescent drencher section signs (ISO 15370).
- 3–5
- Extinction, containment, evacuation
A claw bar in every ro-ro space, training on alternatively powered vehicles, ro-ro decks of at least A-30, and recommended safety distances of 6 m from side openings and 8 m (survival craft) or 13 m (embarkation and muster stations) from weather-deck cargo.
On a vehicle deck
For an existing ro-pax ship, Circ.1615 remains the best summary of what IMO considers good practice on a vehicle deck, and many of its recommendations are now required by 2028.
Its patrol advice, which recommends portable thermal imagers during fire rounds, points at the same gap that continuous per-vehicle detection addresses: overheating that starts between rounds, under or inside a vehicle.
On the timeline
Full timeline →- 26 Jun 2019Interim ro-pax fire guidelines issued
MSC.1/Circ.1615, from the EMSA FIRESAFE work: prevention, detection, video, alarms, signage and safety distances for ro-pax vehicle decks.
Discussed in our articles
12 articles cite MSC.1/Circ.1615, newest first.
- El. Venizelos: Five Days on Garage Deck 3Case Studies
- Which Ferry Fire Upgrades Are Worth the Money?Blogs
- Can Crews Find the Right Drencher in Smoke?Blogs
- RoRo Fire Protection: EV Fire DetectionBlogs
- Are Electric Tugmasters a Deck Fire Risk?Blogs
- What Will the Philippines' EV Ferry Rule Say?Blogs
- Are Reefer Trailers a Ferry's Hidden Fire Risk?Blogs
- Are E-Bikes the Ferry Deck's New Fire Risk?Blogs
Sources we checked
These pages are RoRoSAFE’s plain-English summaries, written for orientation and checked against the sources listed. They are not legal advice and do not replace the official text, which prevails. IMO conventions and codes are published by IMO; we link to official and free copies rather than reproducing them.