What Should a Car-Carrier Fire Drill Test?

Whether the fixed system goes in within 15 minutes. New VCSF guidelines swap the routine monthly drill for six fire scenarios of rising severity.
It should test whether the crew can confirm a fire, muster and release the fixed system within about 15 minutes, and what they do when that is not enough. That is the core of the Vehicle Carrier Safety Forum's Fire Drill Guidelines, published by Britannia P&I on 19 October 2026. They replace one generic monthly drill with six scenarios of rising severity, three at sea and three in port.
What do the new guidelines change?
They turn a frequency rule into a scenario plan. SOLAS chapter III requires each crew member to take part in at least one fire drill a month. It also requires a drill within 24 hours of leaving port if more than a quarter of the crew have not drilled on that ship in the previous month. That sets how often a crew drills. It says nothing about what a vehicle-deck fire demands.
The VCSF's document, version 1.0 of June 2026, fills that gap. It supplements the forum's Fire Response High-Level Guidelines of April 2025, and it is principle-based rather than a ship-specific procedure. Every scenario is built on seven response principles: rapid confirmation of the fire after detection, fast muster, safe deployment of crew, early and correct use of the fixed firefighting system, boundaries and containment, ship-shore communication, and escalation to expert help. Early suppression with the fixed system is described as the central focus of all of them.
What does the 15-minute target ask of a crew?
A complete sequence, from alarm to gas or water in the space, inside a quarter of an hour. The first sea scenario, a fire contained by the initial response, runs in this order:
- The alarm sounds and the bridge team responds.
- The fire's location, extent and conditions are confirmed and reported.
- The crew musters, and firefighting and rescue tactics are agreed.
- The fixed system is deployed as soon as reasonably practicable, always with an objective of within 15 minutes of the alarm.
- A fire team deploys where it is safe, for example to assess the fire's status.
- Shore support is contacted, smoke, vapour, gas and fire boundaries are set, boundary cooling is considered, and monitoring begins.
Measured against the record, that is demanding. Honor's 2017 fire in the English Channel is the fastest documented CO₂ release on a car carrier. The NTSB timeline runs from a pre-warning alarm at 0302 to gas in the space at 0339, which is 37 minutes. That crew did nearly everything right, and they still took more than twice the VCSF objective. The point of a timed drill is to find where those minutes go before a real fire does.
The guidelines also separate ships by system type. On ships with CO₂ or foam, drills must reflect the requirement for full muster and accountability before release, so the headcount sits on the critical path. On ships with deluge or water mist, drills may include a release ordered before muster is complete, or with crew members unaccounted for. That is a decision a master should rehearse before facing it for real.
Why drill fires that cannot be contained?
Because the expensive car-carrier casualties are the ones where the first response failed, and those decisions are the hardest to improvise. The second sea scenario assumes the fire is not controlled at first but can be held within one fire zone. It exercises sustained firefighting, boundary management and early contact with external experts. It adds a table-top element on liaison with salvors and firefighting specialists, the risk of re-ignition and the choice of a port of refuge.
The third assumes the fire cannot be contained. It moves the crew from firefighting to abandonment readiness, with escape routes secured early. The guidelines add a warning drawn from recent incidents: smoke and heat can cut off the usual abandon-ship routes and muster points. On Fremantle Highway in 2023, seven of the 23 crew jumped about 30 metres to escape and one died, after the Dutch Safety Board found rescue had come too late. The VCSF also suggests that shore staff, not the ship, should coordinate external experts, and that companies agree a firefighting specialist's number before any incident.
What changes when the drill is in port?
The cast. Port drills should regularly include port authorities, coast guards, stevedores and terminal operators. The guidelines single out port and municipal fire services as very beneficial for familiarisation and strongly encourage involving them. They admit an operator cannot trigger a multi-party drill alone and suggest working with regularly visited ports to set one up.
The reason is on record. At Port Newark in 2023, two firefighters died fighting the Grande Costa d'Avorio fire. The NTSB found the local fire division had little or no marine firefighting training or familiarity with cargo ships. The in-port scenarios follow from that. The ship's crew briefs the fire service incident commander on how crew can safely support the shore attack. Muster counts shore personnel aboard. Where anyone is unaccounted for, the drill shifts from firefighting to search and rescue.
A final section lists what operators should be ready to hand shore responders:
- General arrangement plans with the incident marked, and fire-zone layouts
- Fixed-system details and status
- Cargo information and declarations
- Ramp, door and movable-deck configuration, and where their controls are
- Personnel numbers and emergency duties
- Stability condition and limits on water application
- Gas and temperature monitoring data
- Fuel and energy storage details, including batteries
The item on controls matters more than it looks. At Newark, a fire-boundary door could not be closed because its controls sat inside the fire zone.
How should an operator put them to work?
Time the drills, and break them down. The guidelines recommend focused drills alongside the full scenarios: fast-muster drills, space close-down drills for sealing cargo and machinery spaces, especially during port operations, fixed-system deployment drills, and realistic use of breathing apparatus so crews learn its limits. They also say drills should adapt to emerging technologies or systems where these are available on board.
- Record the clock at each step: alarm, confirmation, muster complete, openings closed, release. A drill that is never timed cannot show progress against 15 minutes.
- Run at least some drills with the night watch. Honor's alarm came at 0302 and Fremantle Highway's just before midnight.
- Start the drill from a realistic alarm, including one on a deck far from the accommodation, so finding and confirming the fire is part of the test.
- Rehearse the hand-off to shore: who calls the salvor and the firefighting specialist, and what information pack goes with the call.
- In regular ports, ask for a joint drill with the fire service. Then hold the same scenario again in a port that has never seen the ship.
How RoRoSAFE helps
The VCSF's 15-minute clock starts at the alarm, and its first step is confirming where the fire is, how big it is and what is burning. RoRoSAFE places infrared thermal and battery-vent gas sensing under each parked vehicle and sends tiered bridge and shore alerts that name the deck and bay before visible smoke. Its tamper-evident logs and export-ready reports give a timed record for drill debriefs and for shore responders. It complements SOLAS detection and suppression; it replaces neither.
Pilot: one deck · installed alongside the berth · no drydock · 6 months of dashboard access
Sources
- 1. Vehicle Carrier Safety Forum, 'Fire Drill Guidelines for Vehicle Carrying Vessels', version 1.0 (June 2026), read in full from the PDF published by Britannia P&I. It covers the seven core response principles; Section 1 (Scenarios 1.1–1.3 at sea, including the fixed-system objective of within 15 minutes of alarm and the notes on CO₂ or foam versus deluge or water mist, abandon-ship routes and shore coordination of experts); Section 2 (Scenarios 2.1–2.3 in port and the stakeholder list); Section 3 (focused drills); and Section 4 (information for shore responders).
- 2. Britannia P&I, 'Fire drill guidelines for vehicle carrying vessels' (19 October 2026).
- 3. Vehicle Carrier Safety Forum, 'Fire Response – High Level Guidelines' (15 April 2025), as summarised in this site's post on the VCSF 10–15-minute response window.
- 4. SOLAS chapter III, regulation 19.3: every crew member to take part in at least one abandon-ship drill and one fire drill every month, and a drill within 24 hours of leaving port where more than 25% of the crew have not drilled on board in the previous month. See The Nautical Institute, 'SOLAS onboard drill requirements' (HE01195).
- 5. NTSB, Marine Accident Brief NTSB/MAB-18/07, 'Fire on board Vehicle Carrier Honor': 0302 pre-warning alarm to 0339 CO₂ release, as summarised in this site's Honor case study.
- 6. NTSB, Marine Investigation Report MIR-25/16, 'Fire aboard Roll-on/Roll-off Container Vessel Grande Costa D'Avorio' (board meeting 15 April 2025): two Newark firefighters killed; little or no marine firefighting training in the local fire division; fire-boundary door controls inside the fire zone.
- 7. Dutch Safety Board (Onderzoeksraad voor Veiligheid), 'Emergency assistance Fremantle Highway' (28 May 2025): seven of 23 crew jumped about 30 m; one died.
Questions, answered
What are the VCSF fire drill guidelines?+
They are a principle-based framework from the Vehicle Carrier Safety Forum for fire drills on car carriers, ro-ros and ro-pax ships, published by Britannia P&I in October 2026. They set out six scenarios, from a fire controlled by the first response to an uncontainable fire, at sea and in port. Early use of the fixed firefighting system is the central focus throughout.
How fast should a car carrier release its fixed fire system?+
The VCSF guidelines say as soon as reasonably practicable, always with an objective of within 15 minutes of the alarm. For comparison, the fastest documented car-carrier CO₂ release, on Honor in 2017, took 37 minutes. CO₂ and foam systems also require a full muster and headcount before release, which drills should practise.
How often must a car carrier hold fire drills?+
SOLAS requires every crew member to take part in at least one fire drill a month. A drill is also required within 24 hours of leaving port if more than a quarter of the crew have not drilled on that ship in the previous month. The VCSF guidelines address what those drills should cover, not how often they happen.
Should shore firefighters join a ship's fire drill?+
The VCSF strongly encourages it. Port drills should regularly include port and municipal fire services, port authorities, coast guards and stevedores. The NTSB found that the Newark firefighters who died on Grande Costa d'Avorio in 2023 had little or no marine firefighting training, and joint drills are how fire services become familiar with the ships.
Continue the thread

The VCSF 10–15 Minute Rule & Detection Gap
The VCSF Fire Response guidance gives a master 10–15 minutes to control a vehicle fire before activating fixed systems — and the clock starts at detection.

Honor: Thirty-Seven Minutes to CO₂
The 2017 Honor fire is the fastest documented CO₂ release on a car carrier — alarm 0302, gas 0339. It emptied the ship's CO₂ and still cost $700,000.

Is a 22-Person Crew Enough for a Car-Deck Fire?
Enough to release CO₂ fast, not to fight the fire by hand. Car carriers sail with about 22 crew for 13 decks, so time, not headcount, decides it.

Grande Costa d'Avorio: Fatal Loading Fire
The NTSB traced the fatal 2023 Grande Costa d'Avorio fire to a Jeep used as a cargo pusher — and a CO2 system the crew could not seal off.

Are Ports Ready to Fight a Ship Fire?
Mostly not. The NTSB's 2025 safety alert found land firefighters lack the marine training in-port vessel fires demand — after deaths at Port Newark.

When Should a Car-Carrier Crew Abandon Ship?
When the fixed system stops holding. Min Jiang Kou put 22 crew in lifeboats in August 2026; AMVER ships had them aboard within 23 hours.
Referenced in
- Can a Language Gap Slow a Ship's Fire Response?Blogs
- Holiday Island: The Repair That Fed the FireCase Studies
- Pyxis: Fire Out, Chief Engineer Lost to CO₂Case Studies
- Should a Drencher Be Released From the Bridge?Blogs
- Mutiara Sentosa II: Smoke, Then the SeaCase Studies
- RoRo Fire Protection: EV Fire DetectionBlogs