All Blogs

Is a 22-Person Crew Enough for a Car-Deck Fire?

By Vignesh Durai · · 5 min read

Enough to release CO₂ fast, not to fight the fire by hand. Car carriers sail with about 22 crew for 13 decks, so time, not headcount, decides it.

Enough to run the fixed system, not enough to fight the fire by hand. A large car carrier sails with roughly 21 to 23 people for 13 vehicle decks and up to 7,500 cars. On the car-carrier fires that went well, that crew's job was to seal the space, count heads and release CO₂ quickly. The number that decides the outcome is the minutes it takes, not the size of the crew.

21
Crew aboard Honor, a 13-deck, 5,000-vehicle carrier, when fire broke out in 2017
22
Crew who abandoned Min Jiang Kou, a 7,500-vehicle, 13-deck PCTC, in August 2026
37 min
Honor's time from first alarm to CO₂ release, the fastest documented
2
Firefighter's outfits SOLAS requires as a minimum on a cargo ship

How many people crew a car carrier?

About two dozen, almost regardless of size. Felicity Ace had 22 crew when she caught fire off the Azores in 2022. Fremantle Highway had 23 in the North Sea in 2023, and Sincerity Ace had 21 in the Pacific in 2018. Min Jiang Kou, a two-year-old LNG dual-fuel carrier for 7,500 vehicles across 13 decks, was abandoned by 22 crew after an engine-room fire in August 2026. Honor, the US-flag carrier whose 2017 fire is the benchmark for a fast response, carried 21 people for 13 decks and about 5,000 vehicles.

That is several hundred vehicles per person on board, and the person count includes officers, engineers, ratings and catering staff. In any emergency some of them must stay on the bridge and in the engine room. No international rule sets the number. IMO Resolution A.1047(27), the Principles of Minimum Safe Manning, is goal-based. It asks that a ship's complement be able to operate all firefighting and emergency equipment and to muster and disembark everyone aboard. It also asks the company to show the flag state how its proposed complement will handle emergencies and peak workload. The flag administration then issues each ship's minimum safe manning document.

What does a car-deck fire ask of the crew at once?

At least six jobs in different parts of the ship, all inside about half an hour. Honor's timeline, from the NTSB's account, shows the load. At 0302 a pre-warning alarm pointed at the garage deck and the second mate sent an able seaman aft. By about 0305 he had found smoke and fire. The general alarm sounded at 0311 and the first muster was complete at about 0320. Flames were visible outside the compartment at 0325. Ventilation was confirmed shut at 0328, a second muster was taken at 0336, and CO₂ went in at 0339.

  • Bridge: navigate the ship, which was in a traffic separation scheme in near-gale conditions on Honor, and handle the coastguard, the company and the distress traffic.
  • Engine room: start fire pumps, stand by the CO₂ bottles and keep power and propulsion available. Honor's engine room was unmanned at night, so engineers had to get there first.
  • Openings: shut fans, dampers and doors on the affected deck and those connected to it, often on several levels.
  • Headcount: muster everyone and confirm that nobody is in the space before gas is released. Honor did this twice.
  • Boundaries: cool decks and bulkheads above, below and beside the fire to stop it spreading.
  • Scene: a breathing-apparatus pair to investigate, report and withdraw.

SOLAS sets the floor for that last job low. Regulation II-2/10.10.2.1 requires at least two firefighter's outfits on a cargo ship, and regulation II-2/10.10.4 requires two two-way portable radios for each fire party. The shipboard model is a small number of breathing-apparatus teams, not a fire brigade.

Why can't more hands fight the fire directly?

Because a loaded car deck cannot be crossed once it fills with smoke. The NTSB walked Honor's garage deck afterwards and found cars stowed close together with multiple lashings. In the fire, thick black smoke had reduced visibility to nothing. Its conclusion was that the stowage would have made it virtually impossible for the crew to move through the space. Doubling the crew does not widen the gap between cars.

The industry guidance follows the same logic. The Vehicle Carrier Safety Forum's fire-response guidelines of April 2025 note that a vehicle fire, petrol or electric, reaches peak heat release in about 6 to 10 minutes. They recommend switching to the fixed firefighting system if the fire is not under control within 10 to 15 minutes. A crew of 22 or a crew of 40 meets the same fire on the same clock. What headcount changes is how fast the preparation for the fixed system gets done.

Where does a small crew lose the time?

In finding the fire, closing the space and deciding to leave. Each step falls on the same few people.

Finding it: a zone alarm names a deck, not a vehicle. Honor's fire started next to the accommodation, so the master and chief mate were looking at the smoke within minutes. The same alarm eight ramps down would have meant a longer walk, with fewer people left on the bridge while someone made it.

Closing it: a fixed gas system works only inside a sealed boundary. At Newark in 2023, Grande Costa d'Avorio's crew could not shut a fire-boundary door because its controls sat inside the fire zone, the NTSB found. At Jacksonville in 2020, Höegh Xiamen's CO₂ was delayed while vents stayed open, and the ship became a total loss. Every opening that has to be closed by hand is a job for someone who is then not doing anything else.

Leaving: on Fremantle Highway the crew asked to be evacuated at about 02:30, and rescue helicopters arrived about 45 minutes later, after seven of the 23 had jumped from around 30 metres. One died. The Dutch Safety Board found that firefighting and rescue interfered with each other instead of running in parallel. On a ship with two dozen people, fighting the fire and preparing to abandon it draw on the same hands.

Would a bigger crew change the outcome?

At the margins. A second breathing-apparatus team, a faster muster and more people for boundary cooling all help. But no realistic crew size turns a smoke-filled car deck into a space people can work in. The changes that move the outcome are the ones that let the existing crew act earlier and with fewer steps.

  • Plan the fire muster for the night watch, not the day complement. Honor's alarm came at 0302 and Fremantle Highway's just before midnight.
  • Count the tasks against the people. Write down who closes which openings on which deck, who stands at the CO₂ bottles and who keeps the headcount, then check the plan still works with the minimum on watch.
  • Move closures to remote control where possible. Ventilation and boundary doors that can be shut from the bridge or from outside the zone save people as well as minutes.
  • Drill the full CO₂ sequence against the clock, two musters included, so the first time it is timed is not the real fire.
  • Agree the evacuation trigger before the alarm, as the VCSF and IUMI both urge. A crew that size cannot improvise the choice between fighting and leaving.

Manning is a fair question for flag states and owners. On today's evidence, though, a car carrier's crew is sized for the fixed-system response, and the fixed-system response works when it starts early.

Conclusion

How RoRoSAFE helps

A crew of about 22 cannot search 13 decks, but it can seal one space and release CO₂ fast if it knows where to go. RoRoSAFE places infrared thermal and battery-vent gas sensing under each parked vehicle, and its tiered alerts name the deck and bay before visible smoke. The first person sent goes to the right place, and the bridge can start the fixed-system sequence sooner. It complements SOLAS detection and suppression; it replaces neither.

Pilot: one deck · installed alongside the berth · no drydock · 6 months of dashboard access

Sources

  • 1. IMO, Resolution A.1047(27), Principles of Minimum Safe Manning (adopted 30 November 2011), read in full from the IMO PDF. Annex 1 §3.1.2.2: the ability to operate all onboard firefighting and emergency equipment and life-saving appliances, and to muster and disembark all persons on board. Annex 3 §1.2.3–1.2.5: the company assesses the numbers needed for emergency situations, justifies how the complement will deal with them, and ensures manning meets peak workload.
  • 2. SOLAS chapter II-2, regulation 10.10.2.1 (at least two firefighter's outfits on cargo ships) and regulation 10.10.4 (two two-way portable radiotelephones per fire party, for ships constructed on or after 1 July 2014). See IRClass Technical Circular 179/2018 and Lloyd's Register Class News 18/14.
  • 3. NTSB, Marine Accident Brief NTSB/MAB-18/07, 'Fire on board Vehicle Carrier Honor' (DCA17RM007): the 0302–0339 timeline, the stowage and visibility finding, and the 13-deck, ~5,000-vehicle ship, as summarised in this site's Honor case study. Marine Log and Maritime Executive (February 2017), citing HM Coastguard: 21 crew aboard.
  • 4. Felicity Ace: 22 crew evacuated, 16 February 2022 (contemporary casualty reporting, as cited in this site's Felicity Ace case study). Sincerity Ace: 21 crew, 31 December 2018 (gCaptain; US Coast Guard JRCC Honolulu). Min Jiang Kou: 22 crew, 7,500 vehicles, 13 decks, 6 August 2026 (US Coast Guard via gCaptain; WorldCargo News).
  • 5. Dutch Safety Board (Onderzoeksraad voor Veiligheid), 'Emergency assistance Fremantle Highway' (28 May 2025): 23 crew, evacuation request ~02:30, helicopters ~45 minutes later, seven crew jumped about 30 m and one died, and firefighting and rescue tasks interfered with each other.
  • 6. NTSB, Marine Investigation Report MIR-25/16, 'Fire aboard Roll-on/Roll-off Container Vessel Grande Costa D'Avorio': fire-boundary door controls inside the fire zone. NTSB, Marine Accident Report MAR-21/04, 'Höegh Xiamen', as summarised in this site's Honor and Höegh Xiamen case studies.
  • 7. Vehicle Carrier Safety Forum, 'Fire Response – High Level Guidelines' (15 April 2025): peak heat release in about 6 to 10 minutes, and the switch to fixed firefighting at 10 to 15 minutes. IUMI, 'Risk mitigation for the safe ocean and short-sea carriage of electric vehicles' (September 2025).
Frequently asked

Questions, answered

How many crew does a car carrier have?+

Usually about 20 to 25. Felicity Ace had 22, Fremantle Highway 23, Sincerity Ace 21, and the 7,500-vehicle Min Jiang Kou 22. The number is set ship by ship in the flag state's minimum safe manning document, under IMO's goal-based Resolution A.1047(27), rather than by any fixed international figure.

Can a car-carrier crew put out a vehicle-deck fire by hand?+

Rarely, once the deck is smoke-logged. The NTSB found that on Honor's garage deck the close stowage and lashings, with smoke cutting visibility to nothing, would have made moving through the space virtually impossible. Industry guidance therefore puts the fixed CO₂ or drencher system ahead of manual attack, switching to it within 10 to 15 minutes.

How long does it take to release CO₂ on a car deck?+

On Honor in 2017, the fastest documented case, it took 37 minutes from the first alarm. The crew had to confirm the fire, sound the general alarm, muster everyone, shut ventilation, cool boundaries and take a second headcount before releasing gas. Fires found later or further from the accommodation have taken much longer.

Does IMO set a minimum crew for firefighting?+

Not as a number. Resolution A.1047(27) requires that the crew be able to operate all firefighting and emergency equipment and to muster and disembark everyone aboard. It asks the company to show the flag state how its proposed complement will handle emergencies and peak workload. SOLAS separately requires at least two firefighter's outfits on a cargo ship.

Related reading

Continue the thread

CasualtyCO2
Sep 15, 2026 · 7 min read

Honor: Thirty-Seven Minutes to CO₂

The 2017 Honor fire is the fastest documented CO₂ release on a car carrier — alarm 0302, gas 0339. It emptied the ship's CO₂ and still cost $700,000.

By Vignesh DuraiRead
SafetyOperations
Jun 30, 2026 · 3 min read

Are Crews Trained to Fight an EV Fire?

Mostly not. STCW firefighting training is generic — and a battery in thermal runaway can't be put out by routine crew firefighting at all.

By Vignesh DuraiRead
VCSFOperations
Jun 24, 2026 · 2 min read

The VCSF 10–15 Minute Rule & Detection Gap

The VCSF Fire Response guidance gives a master 10–15 minutes to control a vehicle fire before activating fixed systems — and the clock starts at detection.

By Vignesh DuraiRead
SafetyOperations
Aug 18, 2026 · 6 min read

When Should a Car-Carrier Crew Abandon Ship?

When the fixed system stops holding. Min Jiang Kou put 22 crew in lifeboats in August 2026; AMVER ships had them aboard within 23 hours.

By Vignesh DuraiRead
CasualtyIndustry
Jun 27, 2026 · Updated Nov 9, 2026 · 4 min read

Fremantle Highway — Anatomy of a Late Rescue

The Dutch Safety Board faulted the Fremantle Highway rescue; Panama's flag-state report traced the fire to an EV. Seven crew jumped ~30 m and one died.

By Vignesh DuraiRead
OperationsSafety
Sep 25, 2026 · 4 min read

The First Ten Minutes After an EV Alarm

Detection buys time only if the crew knows what to do with it. On a vehicle carrier the decisive variable isn't the alarm — it's the rehearsed response.

By Vignesh DuraiRead