In brief
SOLAS sets fixed air-change rates for vehicle decks: 6 or 10 per hour while vehicles are aboard. Since 1 January 2017 a ship may run lower rates if an air quality control system, built on these guidelines, measures the atmosphere and adjusts the fans.
The guidelines describe ventilation design, measurement of air changes, and an air quality approach based on carbon monoxide (CO), nitrogen dioxide (NO₂) and flammable gas (LEL) readings, with audible and visual alarms when thresholds are exceeded.
Who it applies to
- Ventilation of closed vehicle spaces, closed ro-ro spaces and special category spaces.
- Member Governments are invited to apply it to all ships on a voluntary basis. It becomes the reference when a ship uses the air quality control option in SOLAS II-2/20.3.1.2.4.
What it requires
- Parts 1–2
- Design guidelines and operational recommendations
Ventilation design for ro-ro cargo spaces, the hazardous substances in vehicle exhaust, and recommendations for operating the system, including on car carriers and ships carrying heavy vehicles.
- Appendix 1
- Air quality control and management
Requirements for air quality control systems, the minimum air quantity based on measured CO, NO₂ and LEL, gas detection, and approval testing. One sensor section should cover no more than one hold.
- Appendix 1, 2.10
- Alarms
An audible and visual alarm at a continuously manned location when CO, NO₂ or flammable gas concentration exceeds the threshold.
- Appendix 2
- Air flow testing
Procedures for measuring nominal air changes and air distribution in the space.
On a vehicle deck
Ventilation and detection interact. Air moving through a vehicle deck dilutes and displaces smoke and gas before they reach a ceiling detector, which is why SOLAS requires detection to be tested 'under normal ventilation conditions'.
An air quality control system already measures the deck atmosphere for exhaust gases. It is not a fire detection system and is not approved as one.
On the timeline
Full timeline →- 1 Jan 2017Air quality control option in force
Ships with an air quality control system built to MSC.1/Circ.1515 may run vehicle-deck ventilation below the fixed air-change rates.
Discussed in our articles
3 articles cite MSC.1/Circ.1515, newest first.
Sources we checked
- IMO — MSC.1/Circ.1515, 8 June 2015: revised by SSE 2 (23 to 27 March 2015), approved at MSC 95 (3 to 12 June 2015), supersedes MSC/Circ.729 (MSC 66, 1996), voluntary application; Appendix 1 on CO, NO₂ and LEL, 2.6 and 2.10; Appendix 2 air flow testing. (opens in a new tab)
- IMO — Resolution MSC.392(95), adopted 11 June 2015, in force 1 January 2017: SOLAS II-2/20.3.1.2.4 air quality control option. (opens in a new tab)
These pages are RoRoSAFE’s plain-English summaries, written for orientation and checked against the sources listed. They are not legal advice and do not replace the official text, which prevails. IMO conventions and codes are published by IMO; we link to official and free copies rather than reproducing them.