In brief
Regulation 20-1 is the only SOLAS regulation written for a specific alternative fuel in vehicle cargo. It was added because hydrogen and natural gas leak upward and have ignition properties that petrol-based rules do not cover.
It applies on top of Regulation 20, not instead of it. It does not cover battery-electric vehicles, which are treated by the general vehicle-space rules and, for dangerous-goods purposes, by the IMDG Code.
Who it applies to
- Vehicle carriers whose vehicle and ro-ro spaces are intended for motor vehicles with compressed hydrogen or compressed natural gas in their tanks for their own propulsion.
- Paragraphs 3 to 5 apply to vehicle carriers constructed on or after 1 January 2016. Paragraph 5 (portable gas detectors) also applies to vehicle carriers constructed before that date.
What it requires
- 20-1.3
- Compressed natural gas (new ships)
All electrical equipment and wiring certified safe for an explosive methane and air mixture, including in ventilation ducts; fans designed so they cannot ignite the mixture, with wire-mesh guards on inlets and outlets; no other ignition sources.
- 20-1.4
- Compressed hydrogen (new ships)
The same measures for hydrogen and air mixtures, plus exhaust duct outlets sited in a safe position away from other ignition sources.
- 20-1.5
- Portable gas detection (all vehicle carriers)
When any such vehicle is carried, at least two portable gas detectors suitable for the fuel and certified safe for the explosive gas mixture.
- 20.3.1.2.4
- No ventilation relaxation
The air quality control relaxation of ventilation rates in Regulation 20 does not apply to spaces covered by Regulation 20-1.
On a vehicle deck
Regulation 20-1 is mostly about not igniting a gas release: certified equipment, safe fans and no stray ignition sources. Its detection requirement is two portable instruments, which the crew carry when checking the space.
A fixed detection layer that watches each vehicle for heat and gas is not required by this regulation. Where one is fitted on a deck carrying these vehicles, its electrical equipment has to meet the same certified-safe requirement as everything else in the space.
On the timeline
Full timeline →- 1 Jan 2016Regulation 20-1 in force
Vehicle carriers carrying cars with compressed hydrogen or natural gas in their tanks get certified-safe equipment and portable gas detector requirements.
Discussed in our articles
1 article cites SOLAS II-2/20-1, newest first.
Sources we checked
- IMO — Resolution MSC.365(93), adopted 22 May 2014, in force 1 January 2016: new Regulation 20-1, paragraphs 1 to 5. (opens in a new tab)
- IMO — Resolution MSC.421(98), adopted 15 June 2017, in force 1 January 2020: revised Regulation 20-1 paragraph 2.1. (opens in a new tab)
- IMO — Resolution MSC.392(95), adopted 11 June 2015: Regulation 20.3.1.2.4 excludes Regulation 20-1 spaces from the ventilation relaxation. (opens in a new tab)
These pages are RoRoSAFE’s plain-English summaries, written for orientation and checked against the sources listed. They are not legal advice and do not replace the official text, which prevails. IMO conventions and codes are published by IMO; we link to official and free copies rather than reproducing them.