How Fast Does Smoke Fill a Car Deck?

In minutes, from the deckhead down. Ceiling cameras go blind first: on Commodore Clipper all of them lost the picture 17 minutes after the first haze.
In minutes, and from the top down. Smoke from a vehicle fire rises to the deckhead, spreads along it and thickens downwards, so the ceiling cameras lose the picture first and the crew's view goes next. On Commodore Clipper in 2010 the first camera began to haze at 02:37 and every camera had lost visibility to smoke by 02:54. Once a loaded deck is smoke-logged, crews cannot reach the fire.
That clock decides whether a car-deck fire is fought by hand or by the fixed system. The EU's FIRESAFE II study defined 'early' detection in exactly these terms: the time until conditions around the fire become untenable must be longer than the time needed to detect the fire and organise a first response. If smoke wins that race, the only remaining options are the drencher or CO₂, a smoke-logged evacuation and a long wait.
How does smoke behave on a vehicle deck?
It rises, hits the deckhead and runs along it as a layer that deepens downwards. A burning vehicle sends a plume of hot gas straight up; under the steel above, the plume turns into a ceiling jet that spreads in every direction until it meets beams, bulkheads or the ends of the space. The layer then thickens towards the deck. On a ro-pax main deck with a deckhead of 5 m or more there is some reservoir before the layer reaches head height; on a 2.5 m car deck there is almost none.
Two features of vehicle decks make it worse. They are long open spaces: FIRESAFE II, carried out for EMSA by Bureau Veritas, RISE and Stena, lists smoke filling the whole ro-ro space among its hazards, because nothing divides it, and notes that firefighting can become impossible for lack of visibility. And they are ventilated continuously, which stirs the layer into the air below instead of letting it stratify neatly. Doors to the space are generally not smoke-tight either, because the fire test code does not test them for it, so smoke reaches stairways and accommodation once doors are opened for firefighting.
What does the incident record show?
A window measured in minutes, closed by smoke before anyone reached the fire.
- Stena Spirit, 2016: CCTV showed flames at 06:35:23, three and a half minutes before the deck's smoke detector alarmed at 06:38:54.
- Commodore Clipper, 2010: camera 7 began to haze at 02:37 and by 02:54 the CCTV had lost all visibility to smoke.
- Joseph and Clara Smallwood, 2003: within minutes of discovery the senior officer sent to look could not get near the fire for heavy black smoke, and the chief engineer opening a door to the deck could see nothing.
- Honor, 2017: thick black smoke reduced visibility on the garage deck to nothing, and the NTSB noted that a loaded car deck cannot be entered once smoke-logged.
- Sunflower Daisetsu, 2015: a crew member trying to work round a burning truck lost his bearings in smoke so dense he could not see a metre; the second officer died in the fire.
When does a car deck become untenable?
When visibility, heat or radiation passes a limit a firefighter can work in. The LASH FIRE project's ventilation study used three: visibility below 10 m, gas temperature above 60 °C and incident radiation above 2.5 kW/m². It modelled a closed ro-ro space 162 m long, 25.6 m wide and 5.8 m high with a steady 5 MW fire, about the size of one burning car, and measured where each limit was reached. Radiation was never the constraint: it stayed below 2.5 kW/m² beyond 4 m of the fire in every scenario. Heat and smoke were. With the fans off, gas at 1.9 m, roughly head height, passed 60 °C after about 10 minutes, and for a fire in the middle of the deck it did so across most of the space. Even in the best ventilated case, visibility was down to 10 m only from 10 m away from the fire, and worse closer in.
Toxicity adds a limit crews cannot see. RISE's BREND 2.0 simulations found ventilation was the single biggest factor in how toxic a ro-ro space fire became: in a closed space the toxicity limits were far exceeded, while in a well-ventilated one the values stayed below them except close to the deckhead, and an electric-car fire was only slightly worse than a petrol one.
Do the fans help or hurt?
Early on, they can help the crew; once the fixed system is used, they must stop. The routine on confirming a ro-ro space fire is to stop the mechanical fans and close the fire dampers. In LASH FIRE's simulations, keeping the fans running held head-height temperatures generally below 60 °C, and reversing the fans so that the fire sat near an exhaust held them below 40 °C all the way to the fire. Running reversed at 16 air changes an hour gave the best visibility, and 1:8 model-scale tests confirmed that the fans reduced smoke in the space. The project's conclusion is that mechanical ventilation could help manual firefighting in the early phase, and that reversible fans are worth having. It applies only up to about 5 MW, one burning car; above that, the report says, the practice of shutting down ventilation and starting the extinguishing system is not challenged. Fire spread was not modelled, and the ship's own fans need to be checked and the strategy practised on board first.
That does not contradict the case for stopping the fans: a gas system needs a sealed space, and a fire that has grown beyond hand-held reach is fed by the air the fans supply. The decision is a sequence rather than a rule: ventilate to keep the deck workable while a team can still reach a small fire, then shut down and seal when the response moves to the drencher or CO₂.
What does it mean for detection on a vehicle deck?
The sensors at the deckhead are in the first place the smoke goes, and the first place to lose their view.
- Cameras: SOLAS II-2/20 as amended by MSC.550(108) requires passenger-ship vehicle decks to have cameras mounted high enough to see over the cargo. They are valuable for the first minutes and then sit in the smoke layer; confirmation by camera has to happen early or it does not happen.
- Ceiling detectors: smoke reaches them quickly, but continuous ventilation dilutes it on the way, which is why a detector can alarm after the camera already shows flames.
- Location: once the deck is smoke-logged, the crew cannot find the burning vehicle by looking. Knowing the deck, section and bay before that point is what lets the right drencher section open.
- People: a deck that fills in minutes is no place for drivers who stayed with their vehicles, and an alarm has to reach the space itself.
How RoRoSAFE helps
Smoke fills a car deck from the deckhead down and takes the crew's view, and the cameras', within minutes. RoRoSAFE watches each parked vehicle from beneath with infrared thermal and battery-vent gas sensing, flagging a developing battery fault before visible smoke and sending tiered bridge and shore alerts that name the deck and bay. That points the response at the right section while it can still be seen. It complements SOLAS detection and suppression, and replaces neither.
Pilot: one deck · installed alongside the berth · no drydock · 6 months of dashboard access
Sources
- 1. LASH FIRE (EU Horizon 2020, grant 814975) — Deliverable D11.5, 'Elucidation and guidelines for ro-ro space ventilation in case of fire', May 2023 (V03, coordinated by RISE): CFD of a steady 5 MW fire in a 162 × 25.6 × 5.8 m closed ro-ro space against 60 °C, 2.5 kW/m² and 10 m visibility limits; head-height temperature above 60 °C after about 10 minutes with fans off; reversible fans and 16 air changes per hour; 1:8 model-scale tests; Annex A guideline on mechanical ventilation in closed ro-ro spaces (read in full).
- 2. EMSA — FIRESAFE II, Containment and Evacuation, Final Report v1.1, December 2018 (Bureau Veritas, RISE, Stena Rederi): definition of early detection by available versus required time for safe first response; smoke filling the whole ro-ro space; doors not smoke-tight under the FTP Code; smoke subdivision measures (read in full).
- 3. RISE Research Institutes of Sweden — F. Evegren and M. Arvidson, 'Fire safety with electric vehicles onboard: Should we be worried?', The Swedish Club webinar, 26 April 2023: BREND 2.0 findings on ventilation and toxicity in ro-ro space fires (read in full).
- 4. UK Marine Accident Investigation Branch — Report 24/2011, fire on the main vehicle deck of Commodore Clipper, 16 June 2010: CCTV haze from 02:37 and loss of all CCTV visibility by 02:54.
- 5. State Marine Accident Investigation Commission (PKBWM), Poland — Final Report WIM 60/16, truck fire on the car deck of Stena Spirit, 31 August 2016: CCTV flames at 06:35:23, smoke detector alarm at 06:38:54.
- 6. Transportation Safety Board of Canada — Marine Investigation Report M03N0050, Joseph and Clara Smallwood, 12 May 2003: heavy black smoke preventing access to the fire on vehicle deck 1 (read in full).
- 7. National Transportation Safety Board — Marine Accident Brief MAB-18/07, fire on board vehicle carrier Honor, 24 February 2017: visibility on the garage deck and entry to a smoke-logged car deck.
- 8. Japan Transport Safety Board — Marine Accident Investigation Report MA2018-9-1, fire on passenger ferry Sunflower Daisetsu, 31 July 2015.
- 9. IMO — Resolution MSC.550(108), in force 1 January 2026: SOLAS II-2/20.4.4 video monitoring of vehicle, special category and ro-ro spaces on passenger ships.
Questions, answered
How long does it take smoke to fill a ferry car deck?+
Minutes rather than hours. Smoke rises to the deckhead, spreads along it and thickens downwards. On Commodore Clipper in 2010 the CCTV went from the first haze to no visibility in 17 minutes. Low decks fill faster because there is little volume above head height, and continuous ventilation mixes the smoke into the air below.
What makes a car deck untenable for firefighters?+
Heat and smoke, not radiation. The EU LASH FIRE project judged conditions against visibility below 10 m, gas temperature above 60 °C and radiation above 2.5 kW/m². For one burning car in a closed deck with the fans off, head-height gas passed 60 °C across most of the space in about 10 minutes, and visibility near the fire fell below 10 m. Toxic gases add a limit nobody can see.
Should the fans be left on during a car-deck fire?+
Only in the early stage, and only by plan. LASH FIRE found that running the fans at increased capacity while the fire is small, up to about 5 MW, can reduce smoke and help manual firefighting before the drencher starts. Once the response moves to the drencher or CO₂, the fans must stop and the space be sealed.
Why do CCTV cameras lose the picture so quickly?+
Because they are mounted high to see over the cargo, which puts them in the smoke layer that forms under the deckhead first. That makes camera confirmation valuable in the first minutes and unreliable afterwards, so the deck, section and bay need to be known before the deck is smoke-logged.
Continue the thread

Does a Battery Vent Plume Reach the Ceiling?
Often not at first. Early electrolyte vapour is 2–3× denser than air and stays low; only the hot runaway gas rises fast enough for ceiling detectors.

Does Deck Ventilation Delay Fire Detection?
Yes. SOLAS II-2/20 mandates continuous ventilation on closed vehicle decks, and that airflow dilutes smoke and off-gas before detectors see it.

Should Car-Deck Fans Stop in an EV Fire?
Yes — stopping the fans starves the fire and lets CO₂ work. But a sealed deck also traps battery vent gas, so when and how you reopen it matters as much.

What Does SOLAS 2026 Video Monitoring Require?
Cameras over every passenger-ship vehicle deck, 7-day playback, each camera mapped to a drencher section, no one required to watch. Cargo ships: nothing.

Commodore Clipper: The Alarm Reset 7 Times
A reefer plug ignited on a Condor ro-pax in 2010. Detection worked — 16 sensors, 81 alarms. The crew read a fault, silenced it, and lost 17 minutes.

Honor: Thirty-Seven Minutes to CO₂
The 2017 Honor fire is the fastest documented CO₂ release on a car carrier — alarm 0302, gas 0339. It emptied the ship's CO₂ and still cost $700,000.

Sunflower Daisetsu: The Fire Inside the Cover
In 2015 a reefer fire on the ferry Sunflower Daisetsu burned inside its cover, beyond 16 extinguishers; the drencher was then overloaded. One crew died.