All Case Studies

Urd: The Fire That Fell From the Deckhead

By Vignesh Durai · · 5 min read

In 2014 a corroded car-deck light on the ro-pax Urd dropped a burning diffuser onto a lorry. Passing engineers found it six minutes before detection.

The fire on Urd did not start in the cargo. On 4 March 2014 a corroded fluorescent light on the main car deck arced, its plastic diffuser caught fire, fell, and set light to the tarpaulin of the lorry parked beneath it. Two engineers walking through the deck to breakfast found it six minutes before the ship's automatic detection did, and the fire was out about half an hour later.

The Danish Maritime Accident Investigation Board classed it as a less serious casualty, and it was: no injuries, a burnt tarpaulin, a damaged lorry and a destroyed light fitting. Its value is that every weakness of a full car deck showed up in a fire small enough to survive. Detection was slow for a known reason, the sprinkler section had to be found from memory in smoke, the deck sprinkler did not finish the job, and firefighters had to climb over the cargo to reach it.

The ship and the crossing

Urd was a ro-pax ferry on Stena Line's Travemünde–Liepāja service, a crossing of about 26 hours carrying mostly driver-accompanied lorries. She sailed from Liepāja at 03:20 on 4 March with 110 passengers, 23 crew and a full main car deck.

  • Passenger/ro-ro ship (vehicles), built 1981 by Nuovi Cantieri Apuania, converted in 1991 and 2001; IMO 7826855; 13,144 GT; 171.05 m; Danish International Register, Lloyd's Register class; owned by Stena Line Baltic A/S.
  • Cargo: 88 lorries, 12 cars, one trailer and two other units, taking 1,614 lane metres against a rated 1,600, with no stowage plan giving each vehicle's position.
  • Car-deck sprinkler system in ten zones, with the section valves at a control station at the forward end of the main deck.
  • Automatic detection: heat detectors in the original forward and aft sections of the main deck, smoke detectors only in the section added amidships in 2001.

How did a light start a lorry fire?

Through corrosion and arcing at the deckhead. The fixture had probably been fitted in 1995, about 10 to 12 cm from a sprinkler head that was tested every week. A reference fixture from the same deck showed a protection level originally around IP44, now badly deteriorated, with corrosion and salt deposits at the tube ends and burn marks from arcing in a socket, where the ballast induced 1,000 to 1,500 volts while repeatedly trying to start worn-out tubes. The DMAIB concluded that age, poor sealing and a humid, saline atmosphere inside the fitting produced a poor connection that arced and ignited the diffuser, which then dropped onto the lorry below.

The first ten minutes

Found by chance, alarmed by hand, and sprinkled from memory. At about 07:40 the second and third engineers crossed the main car deck on their way to breakfast, smelt electrical burning, saw smoke and found flames about 5 cm high and 1.5 m long on top of a lorry. The third engineer ran to the bridge and the chief officer raised the fire alarm at 07:43. The engineers went to the sprinkler control station but were not sure which section the lorry was in; an able seaman there was sure it was section 6, and at 07:50 section 6 was opened.

The automatic system gave its first alarm at 07:46, about six minutes after the engineers found the fire. The lorry stood in an original section about 20 m from the nearest smoke detector, in the 2001 extension, and the small fire had not produced enough heat to trip the heat detectors overhead. Meanwhile smoke had gathered under the deck above, between the deckhead and the lorry roofs, and hid the section numbers painted on the frames along the ship's sides. The DMAIB found that choosing the right valve took particular knowledge of the deck, with no intuitive aids, and that the drawing in the control station showed the sections in the opposite orientation to the person reading it.

~6 min
Crew discovery at 07:40 to the first automatic detection alarm at 07:46
~20 m
Distance from the burning lorry to the nearest smoke detector
10 min
Sprinkler run in section 6 before it was stopped to assess; fire not out
1,614 m
Lane metres loaded on a deck rated for 1,600

Why did the sprinkler not finish it?

Because the fire was inside and on top of the cargo, and the water came from above a full deck. At 08:00, ten minutes after the sprinkler started, the crew asked for it to be stopped because nobody could see anything through the heavy water flow. The deck fans were run in alternating directions to clear the smoke with the stern ramp closed. Small flames were still coming from the trailer.

The hose team then met the problem every full car deck presents. The lorry was in the third lane from the side where they had rigged, with a car and trailer and another lorry in between, and the vehicles were parked too close to approach it. The chief officer climbed onto the cab of the lorry next door, was handed a knife, cut open the burnt tarpaulin and directed the hose onto the cargo inside. The fire was reported out at 08:08, and a fire watch was kept on the deck to Travemünde. The DMAIB found the fixed system only partially effective even against a fire of this limited size.

Passenger muster started at 07:57 and was abandoned at 08:10 when the bridge reported the fire under control. The mechanical counters for the census were missing, and catering crew found it hard to keep passengers together. With a short event that did not matter; the DMAIB noted it, and the company replaced the counters and ordered more radios.

What does Urd teach about full car decks?

That a small fire on a full deck is saved by people, and only just.

  • The deck's own equipment can start fires. A car-deck light sitting next to a regularly tested sprinkler head had probably lived in a humid, salty atmosphere for about 19 years; the DMAIB recommended inspecting every car-deck fixture.
  • Detector layout matters more than detector count. Mixed heat and smoke sections after a conversion left the forward end of the deck covered only by heat detectors that a small fire could not trip.
  • Section markings have to work in smoke. Urd's crew picked section 6 from an able seaman's memory; Stena Line added markings at eye height and redrew the control-station plan, and SOLAS now requires photoluminescent section signs on new ro-pax ships.
  • Access is the limit. With no stowage plan and lorries parked tight, the only way to the fire was over the cargo, and the cargo itself could only be identified by its registration plate and a one-line manifest entry.
Conclusion

How RoRoSAFE helps

Urd's fire began overhead, in the ship's own lighting, and was found by two engineers who happened to walk past. A per-vehicle grid beneath parked cars is built for the other kind of fire, the one that starts in a vehicle, where it flags thermal and battery-vent signs before visible smoke and sends bridge and shore alerts naming the deck and bay. RoRoSAFE complements SOLAS detection and suppression; it does not replace car-deck electrical maintenance or markings crews can read in smoke.

Pilot: one deck · installed alongside the berth · no drydock · 6 months of dashboard access

Sources

Frequently asked

Questions, answered

What caused the fire on Urd?+

A fluorescent light fixture on the main car deck. The DMAIB found that age, poor sealing and a humid, saline atmosphere inside the fitting, which sat 10 to 12 cm from a sprinkler head, produced a poor electrical connection that arced. The plastic diffuser caught fire, fell off and ignited the tarpaulin of the lorry parked underneath.

Why did the automatic detection take six minutes?+

Because of where the detectors were. After a 2001 conversion, only the new midship section had smoke detectors; the original forward section, where the lorry was parked, had heat detectors. The burning lorry was about 20 m from the nearest smoke detector, and the small fire was not hot enough to trip the heat detectors above it.

Did the car-deck sprinkler put the fire out?+

Not completely. Section 6 ran for ten minutes before the crew stopped it to see the effect, and small flames were still coming from the trailer. The fire was finished with a hose by the chief officer, who climbed onto the neighbouring lorry and cut open the burnt tarpaulin. The DMAIB found the fixed system only partially effective.

What changed after the Urd fire?+

Stena Line extended the sprinkler piping so nozzles sit well below the light fixtures, added sprinkler-section markings at eye height, redrew the section plan at the control station, upgraded car-deck CCTV, replaced the passenger census counters and ordered more radios. The DMAIB recommended inspecting all car-deck light fixtures for repair or replacement.

Related reading

Continue the thread

CasualtyDetection
Oct 31, 2026 · 6 min read

Joseph and Clara Smallwood: The Silent Alarm

A 2003 truck fire on a Marine Atlantic ferry was held by the deluge, but no alarm sounded on the vehicle deck. Two people sat trapped for two hours.

By Vignesh DuraiRead
DetectionFirefighting
Nov 2, 2026 · 6 min read

How Fast Does Smoke Fill a Car Deck?

In minutes, from the deckhead down. Ceiling cameras go blind first: on Commodore Clipper all of them lost the picture 17 minutes after the first haze.

By Vignesh DuraiRead
CasualtyDetection
Sep 22, 2026 · 8 min read

Commodore Clipper: The Alarm Reset 7 Times

A reefer plug ignited on a Condor ro-pax in 2010. Detection worked — 16 sensors, 81 alarms. The crew read a fault, silenced it, and lost 17 minutes.

By Vignesh DuraiRead
HardwareDetection
Sep 23, 2026 · 5 min read

The Loose Terminal a Breaker Cannot See

A loose joint changes resistance, not current — so overcurrent protection is blind by construction. MAIB 24/2011: 25 A through a 32 A breaker, and a fire.

By Vignesh DuraiRead
SafetyRegulation
Sep 28, 2026 · 4 min read

Do Fire Patrols Still Work on a Car Deck?

SOLAS still relies on fire patrols in ro-ro spaces. On a packed car deck they confirm alarms far better than they find fires, as four casualties show.

By Vignesh DuraiRead
SuppressionCompliance
Jun 5, 2026 · Updated Oct 24, 2026 · 3 min read

PCTC Drencher Zoning and Fixed-First

Drenchers deliver 5–15 L/min/m² by deck height. Whether 'Fixed First' suppresses or floods a car deck depends on how precisely detection zones it.

By Vignesh DuraiRead