SOLAS II-2/20 Checklist for Ro-Ro Ship Operators

By Vignesh Durai · September 23, 2026 · 6 min read

Four checklists, one per ship type and build date. Most operators owe far less than the 2026 headlines imply — and a car carrier owes almost nothing.

There is no single SOLAS II-2/20 checklist — there are four, and which one you owe depends on two facts: passenger ship or cargo ship, built before or after 1 January 2026. Get that wrong and you either over-specify a car carrier against a passenger-ship rule nobody will ask you for, or you miss a 2028 survey date. Start by finding your row.

This is the actionable companion to the full explainer of the amendment: items phrased as things to verify, with the evidence a surveyor will want to see. Every requirement below comes from the ABS and Lloyd's Register class summaries of Resolutions MSC.550(108) and MSC.555(108), both in force 1 January 2026.

Step 1 — find your row before reading anything else

  • Passenger ship, keel laid on or after 1 January 2026 → the full checklist. Detection, video, suppression, boundaries, openings, ventilation.
  • Passenger ship, constructed before 1 January 2026 → the retroactive checklist, due no later than the first survey on or after 1 January 2028. Detection and video only.
  • Cargo ship, keel laid on or after 1 January 2026 → the short checklist. Fixed detection to FSS Code Chapter 9, and nothing else new.
  • Cargo ship, constructed before 1 January 2026 → no new items. The requirements prior to MSC.550(108) remain applicable.
  • 'First survey' means the first annual, periodical or renewal survey falling due after the date, per MSC.1/Circ.1290 — not the next drydock, and not a date you choose.
A pure car and truck carrier is a cargo ship. If it was built before 2026 this amendment adds nothing to your ship, on any date. The commercial risk is the opposite of the usual one: buying to a passenger-ship specification no surveyor will ask you for.

Checklist A — new passenger ships (from 1 January 2026)

  • Detection is individually identifiable in vehicle, special category and ro-ro spaces, per FSS Code Chapter 9.
  • Combined smoke and heat detectors are fitted throughout those spaces, capable of rapidly detecting the onset of fire. Linear heat detectors may be accepted by the Administration.
  • Detector spacing meets the amended table: combined smoke-and-heat at a maximum 74 m² per detector, 9 m between centres, 4.5 m from bulkheads. Check this against the existing layout — the 74 m² area is a smoke detector's, but the 9 m / 4.5 m spacing is a heat detector's, so an old 11 m smoke grid needs more heads, not just different ones.
  • Detectors below movable ro-ro decks meet the same spacing. Price this before a hoistable-deck arrangement is signed off.
  • Linear heat detection, where used, has sensor cables at most 9.0 m apart and 4.5 m from bulkheads, tested to EN 54-22:2015 and IEC 60092-504.
  • Detection zones align with the deluge system sections where a water-based deluge system is fitted, so a detector zone resolves to a valve.
  • Weather decks intended for vehicle carriage have fixed detection, with detector type, spacing and location approved by the Administration considering weather and obstruction by cargo.
  • Alarm presentation follows a consistent scheme — wording, vocabulary, colour and position — immediately recognisable on the navigation bridge and not compromised by noise or poor placement.
  • The interface provides alarm addressability, lets the crew identify alarm history and the most recent alarms, and allows suppression while keeping alarms with ongoing trigger conditions clearly visible.
  • Video monitoring covers vehicle, special category and ro-ro spaces, with immediate playback, cameras high enough to see over cargo and vehicles after loading, and camera-to-extinguishing-section correspondence displayed near the monitor.
  • Video recordings are replayable at a continuously manned control station or safety centre for at least 7 days.
  • Weather-deck monitors deliver at least 2.0 L/min/m² combined over the protected area, no individual monitor below 1,250 L/min, each sited outside the area it protects, with the farthest forward extent within 75% of the monitor's throw in still air.
  • Boundary bulkheads and decks of special category and ro-ro spaces are A-60 on ships carrying more than 36 passengers, reducible to A-0 in the defined cases; internal deck subdivisions are A-30 where the water-based system cannot cover above and below simultaneously.
  • Openings in side plating, ends or deckhead are clear of survival craft, embarkation and assembly stations and occupied spaces above, with the 6.0 m horizontal exclusion observed; A-0 windows protected by a water curtain of at least 5.0 L/min/m² may be accepted as A-60 equivalent.
  • Ventilation openings below accommodation and control stations have steel or fire-resistant closing devices operable from accessible positions, and none sit below survival craft, emergency generators or engine-room air intakes.

Checklist B — existing passenger ships (by first survey after 1 January 2028)

Shorter than the newbuild list, and that is the point — structural fire protection and the openings rules stay as they were. Four items:

  • Fixed detection is provided in vehicle, special category and ro-ro spaces per FSS Code Chapter 9, capable of rapidly detecting the onset of fire.
  • Combined smoke and heat detectors are installed throughout those spaces. Heat detectors follow the spacing and coverage applicable to smoke detectors, and are required only where a smoke detector already exists — which bounds the retrofit.
  • Video monitoring is fitted to the same specification as a new passenger ship, except that replay capability need only be at least 24 hours rather than 7 days.
  • Existing provisions survive: testing after installation, and the exemption that a fixed detection system is not required where an efficient patrol system is maintained by a continuous fire watch at all times during the voyage.

Checklist C — cargo ships, including car carriers

One item for a newbuild, none for an existing ship. For a cargo ship with a keel laid on or after 1 January 2026: fixed fire detection and alarm in vehicle, special category and ro-ro spaces complying with FSS Code Chapter 9, with detector type, spacing and location subject to Administration approval considering ventilation effects, and the system tested after installation under normal ventilation conditions with the overall response time approved by the Administration. Corridors, stairways, escape routes, control stations and cargo control rooms follow the adopted protection method (IC, IIC or IIIC) under regulation 9.2.3.1.

For a cargo ship built before 1 January 2026 the list is empty — the pre-amendment requirements remain applicable. That is not a loophole to exploit but a planning fact: what will reach the vehicle-carrier fleet is the interim guidelines now being drafted at IMO, with SOLAS text no earlier than 2032, and in the meantime whatever a charterer, class notation or insurer asks for. The companion posts on the compliance calendar and SSE 12 cover that timeline.

74 m² / 9 m / 4.5 m
combined smoke-and-heat detector: max area, max spacing between centres, max distance from bulkheads
7 days / 24 hrs
video replay retention — new passenger ships vs existing ones
2.0 L/min/m²
minimum combined weather-deck monitor capacity, individual output ≥1,250 L/min

What a surveyor will ask to see — and what is not on the list

Evidence, not intentions. The amendment quantifies things that used to be judgement, and quantified items are the ones that get checked: a detector layout drawing dimensioned against the spacing table rather than a generic arrangement; the test record from commissioning under normal ventilation conditions with the approved overall response time; the camera plan validated against a loaded stow condition rather than an empty deck, with the camera-to-section correspondence actually displayed at the monitor; the retention setting on the recorder; monitor capacity calculations for the weather deck; and the disconnection arrangement for smoke detection during loading — which must match the loading duration, reset automatically, indicate its status at the central unit, and must never disable heat detection or manual call points.

What is not on the checklist is as useful to know. There is no required time-to-alarm for a vehicle-deck fire anywhere in this package — spacing and detector type are specified, detection performance is not. There is no requirement for anyone to watch the video: ABS's summary states in terms that continuous crew monitoring is not required. And there is no video requirement for a cargo ship of any age. An operator who reads those three gaps correctly will not confuse a compliant ship with a monitored one, which is the distinction the corpus's posts on video monitoring and alarm credibility are about.

Conclusion

How RoRoSAFE helps

The checklist tells you the minimum you owe. RoRoSAFE is what an operator can add above it: per-vehicle thermal and battery-vent gas detection that alerts before visible smoke, installed alongside the berth without drydock. It is not a SOLAS compliance item and holds no class type approval yet. It works alongside whichever checklist row your ship falls under.

Pilot: one deck · installed alongside the berth · no drydock · 6 months of dashboard access

Sources

  • 1. IMO Resolution MSC.550(108), Amendments to SOLAS Chapters II-2 and V, adopted 23 May 2024, in force 1 January 2026; Resolution MSC.555(108), amendments to FSS Code Chapters 7 and 9; MSC.1/Circ.1290 for the definition of 'first survey'; MSC.1/Circ.1615, the interim guidelines carrying FIRESAFE outcomes.
  • 2. ABS Regulatory News No. 15/2025 (December 2025), 'Fire Safety Requirements for Ro-Ro Passenger and Cargo Ships' — read in full from the published PDF. Source of the four-row application table; the detector spacing figures (heat 37 m²/9 m/4.5 m, smoke 74 m²/11 m/5.5 m, combined 74 m²/9 m/4.5 m); linear heat cable spacing and EN 54-22:2015 / IEC 60092-504 testing; detectors below movable ro-ro decks; deluge-section alignment; the alarm-presentation and addressability provisions; the loading-disconnection conditions; video monitoring with 7-day and 24-hour retention and 'continuous crew monitoring is not required'; weather-deck monitor figures (2.0 L/min/m², ≥1,250 L/min, 75% of throw); A-60/A-0/A-30 boundary ratings; the 6.0 m opening exclusion and 5.0 L/min/m² water-curtain equivalence; ventilation-opening restrictions; and the cargo-ship rows including the patrol-system exemption.
  • 3. Lloyd's Register Class News 07/2026 (1 April 2026), 'SOLAS amendments: Fire Safety Requirements for ro-ro Passenger Ships': application to cargo ships and ro-ro passenger ships constructed on or after 1 January 2026, and existing ro-ro passenger ships not later than the first survey on or after 1 January 2028.
  • 4. Companion RoRoSAFE analyses — 'SOLAS II-2/20 Explained: New Fire Safety Requirements for Ro-Ro Ships in 2026' (the reference version of everything summarised here), 'What Does SOLAS II-2/20 Ask of a Car Carrier?', 'Does the 2026 SOLAS Rule Reach Old Ships?', 'SOLAS 2026 Video Monitoring: Who Is Watching?' and 'Does Car-Carrier Fire Compliance Arrive in 2027?'.
Frequently asked

Questions, answered

Does the SOLAS II-2/20 2026 checklist apply to my car carrier?+

Almost certainly not. A pure car and truck carrier is a cargo ship. If it was built before 1 January 2026 the amendment adds nothing on any date. If the keel was laid on or after that date, the only new item is fixed fire detection to FSS Code Chapter 9 with Administration-approved type, spacing and location — no video monitoring, no new structural requirements.

What is the deadline for existing ro-ro passenger ships?+

No later than the first survey on or after 1 January 2028, where 'first survey' means the first annual, periodical or renewal survey falling due after that date under MSC.1/Circ.1290. The retroactive scope is narrower than the newbuild package: fixed detection with combined smoke and heat detectors throughout, and video monitoring with at least 24-hour replay.

What detector spacing does the 2026 amendment require?+

For ships built on or after 1 January 2026: heat detectors at most 37 m² per detector, 9 m between centres, 4.5 m from bulkheads; smoke at 74 m², 11 m and 5.5 m; combined smoke-and-heat at 74 m² but 9 m and 4.5 m. The combined detector keeps the smoke area while inheriting heat spacing, so a deck laid out to an 11 m smoke grid will need additional heads.

Is there a required detection response time for vehicle decks?+

No. The amendment specifies detector type, spacing, location and testing under normal ventilation with an overall response time approved by the Administration — but it sets no time-to-alarm standard for a vehicle-deck fire. Detection performance remains a design and procurement question, not a regulated figure, which is why a compliant ship is not automatically a well-monitored one.

Related reading

Continue the thread

RegulationSOLAS
Sep 23, 2026 · 7 min read

SOLAS II-2/20 Explained: New Fire Safety Requirements for Ro-Ro Ships in 2026

The 2026 amendment in full: who it binds, the detector spacing table, video monitoring, boundaries and the weather-deck monitors — by ship type and date.

By Vignesh DuraiRead
RegulationSOLAS
Sep 13, 2026 · 7 min read

What Does SOLAS II-2/20 Ask of a Car Carrier?

Almost all of the 2026 amendment is written for passenger ships. A cargo ship gets one detection paragraph; the car-carrier package is still in draft.

By Vignesh DuraiRead
RegulationSOLAS
Sep 14, 2026 · 6 min read

Does the 2026 SOLAS Rule Reach Old Ships?

Only if it is a passenger ship. MSC.550(108) catches existing ro-pax at the first survey on or after 1 Jan 2028; an existing car carrier is not named.

By Vignesh DuraiRead
RegulationRoPax
Sep 23, 2026 · 6 min read

SOLAS 2026 Video Monitoring: Who Is Watching?

Nobody, by design. The rule requires the cameras and the recording — ABS's summary of MSC.550(108) states continuous crew monitoring is not required.

By Vignesh DuraiRead
RegulationDetection
Sep 15, 2026 · 7 min read

Is Individually Identifiable Detection Required?

On a passenger ship, since 2012 — the FSS Code defines the term. On a car carrier, no: MSC.550(108) leaves cargo ships at section identification.

By Vignesh DuraiRead
RegulationDetection
Sep 16, 2026 · 7 min read

What Does SOLAS 2026 Video Monitoring Require?

Cameras over every passenger-ship vehicle deck, 7-day playback, each camera mapped to a drencher section, no one required to watch. Cargo ships: nothing.

By Vignesh DuraiRead
RegulationIndustry
Sep 20, 2026 · 5 min read

Does Car-Carrier Fire Compliance Arrive in 2027?

No. 2027 holds no entry-into-force date. The calendar is 2026 (new passenger ships), 2028 (existing ro-pax) and 2032 at the earliest for PCTCs.

By Vignesh DuraiRead
RegulationSafety
Sep 19, 2026 · 6 min read

Is Fire Detection Off While the Ship Loads?

Usually, yes — smoke sections are muted while loading. From 2026 the FSS Code allows it but keeps heat detection on; 1 in 4 ro-ro fires start in port.

By Vignesh DuraiRead