All Technical Articles

Can AI Video Smoke Detection Work on a Car Deck?

By Vignesh Durai · · 5 min read

Partly. A camera sees a wide area and can spot haze early, but parked cars block its view, and exhaust or condensation can look like smoke to the model.

Partly. AI video smoke detection watches a whole deck at once, and on Commodore Clipper in 2010 the vehicle-deck CCTV hazed about five and a half minutes before the first smoke detector alarmed. But a car deck is a hard place for a camera. Parked vehicles block its view, the lighting varies, and exhaust haze and condensation can look like smoke.

Owners are now buying these systems. MOL has fitted AI cameras to its LNG-fuelled car carrier newbuilds, ClassNK's early-detection notation has been awarded to a ship that relies on AI cameras, and IMO has put interim guidelines for video monitoring and detection systems on its priority list. What these systems detect, and what they cannot see, decides whether a camera adds a detection layer or only a picture.

~5.5 min
Commodore Clipper: deck CCTV hazed at 02:37, first smoke-detector alarm at 02:42:36 (MAIB 24/2011)
10 cm
Typical mirror-to-mirror stowage gap on a car carrier, which leaves a camera little line of sight between vehicles
2–10.8 lux
Minimum scene illumination that vendors quote for video smoke analytics, unless IR illumination is added
2032
Earliest entry into force for SOLAS amendments that follow IMO's vehicle-space review (SSE 12)

How does AI video smoke detection decide it is seeing smoke?

It looks for changes in the image that smoke typically causes, rather than sampling the air. Classic video image smoke detection (VISD) tracks slow-moving regions that soften edges, lower contrast and shift colour towards grey, and that grow and drift the way a plume does. Newer systems add a trained neural network that classifies image regions as smoke or not smoke. Either way, the input is light reflected from the scene, so the camera can only report aerosol that sits in its field of view and is lit well enough to see.

That makes it a different instrument from a deckhead point detector. A point detector waits for smoke to travel to it. A camera can register a haze anywhere along the lane it overlooks, which is why NFPA 72 has covered video image smoke detection since its 2007 edition, and requires the whole system, software included, to be listed for smoke detection.

What could a camera catch that a deckhead detector misses?

Smoke that has not yet reached a detector, and a battery's vent cloud before it ignites. On Commodore Clipper, camera 7 on the port side of the main vehicle deck began to haze at 02:37 while a reefer plug was burning. Sensor D24 alarmed at 02:42:36. Nobody read the haze as fire, because the camera had no analytics and the image looked like a picture fault. By 02:54 all camera visibility had been lost to smoke.

A lithium-ion pack in early runaway can also release a dense white cloud of vent gas, particles and aerosolised electrolyte before any flame. A detection algorithm can see that cloud in a gap it overlooks. The heaviest part of the release tends to stay low, because carbonate solvent vapour is three to four times denser than air, so the cloud may not rise into a deckhead detector for some time.

Where does a car deck defeat the camera?

In three places: line of sight, light and nuisance aerosol. Each is a property of the deck rather than of the algorithm, so a better model does not remove it.

Line of sight

Cars on a carrier are commonly stowed about 30 cm bumper to bumper and 10 cm mirror to mirror. A deckhead camera looking along a lane sees roofs, while an EV pack vents beneath the floor pan. EMSA's FIRESAFE II study found that the area covered by video and flame detectors is 'strongly dependent on the position of mounting and if their field of view is blocked by the cargo'. A vent under the middle of a row may be visible only once it has spread above roof height.

Light

Video analytics need a lit scene. One fire-video vendor quotes a 2 lux minimum, while an earlier industry guide asks for 1 foot-candle, about 10.8 lux, for smoke detection. Both can be met with infrared illumination, but the lighting a deck has at sea becomes part of the detection design and has to be specified, not assumed.

Nuisance aerosol

Exhaust haze, condensation fog and steam scatter light much as smoke does. The FSS Code already accepts this for point detectors: smoke detection in ro-ro spaces on new ro-pax ships may be switched off during loading because vehicle exhaust would trigger it, and heat detection may not. A camera watching the same deck sees the same haze. Published smoke models on general image sets report false-positive rates from about 6% upwards, and name steam, fog and sudden lighting changes as the usual confusers.

None of these false-positive rates were measured on a vehicle deck. A trained model's error rate belongs to the images it was trained and tested on; a loaded deck with exhaust haze, wet decks and moving shadows is a new dataset.

What evidence exists from ships so far?

Owner trials and a class notation, but no published head-to-head detection times. MOL tested Captain's Eye AI cameras on the car carrier Onyx Ace, reported that they detected small amounts of smoke, and in November 2023 announced fitting on 10 LNG-fuelled car carriers on order, with alerts going to the crew and the shore manager. 'K' Line signed a joint development agreement in 2024 with NIPPON HAKUYO electronics and OPT Gate for an optical fire detection system meant to beat existing smoke detectors on speed and accuracy.

In October 2024 ClassNK awarded the AFVC(FD)(EV) notation to Eastern Car Liner's Positive Challenger. Its AI cameras combine smoke detection, heat detection and rapid temperature-rise detection, a pairing of visible and thermal sensing rather than a plain video system. On regulation, SSE 12 (9–13 March 2026) prioritised interim guidelines for video monitoring and detection systems, and a correspondence group will report to SSE 13 in March 2027.

How should an owner specify and test it?

Treat it as an extra detection layer, then prove it on a loaded deck.

  • Ask for the listing or approval evidence for the camera and its software together, and the edition of the model that was tested.
  • Map each camera's field of view against a fully loaded stowage plan. Count the bays it cannot see.
  • Specify the lighting at sea, or IR illumination, to the vendor's stated minimum for detection, not for viewing.
  • Run the trial through loading, port humidity and open ramp doors, and log false alarms per 1,000 camera-hours.
  • Prefer systems that check a visual alarm against a second signal. Fusing image analysis with temperature and humidity has been shown to reject fog and dust alarms.
  • Keep the SOLAS deckhead detection. A camera that sees first still needs a detector that alarms reliably.
Conclusion

How RoRoSAFE helps

A deckhead camera sees roofs while a battery vents under the floor pan. RoRoSAFE places infrared thermal and battery-vent gas sensing beneath each parked vehicle, where neither cargo nor exhaust haze blocks the signal, and sends tiered bridge and shore alerts naming the deck and bay. It complements cameras and the SOLAS detection and suppression systems and replaces neither. RoRoSAFE does not yet hold class type approval.

Pilot: one deck · installed alongside the berth · no drydock · 6 months of dashboard access

Sources

  • 1. MAIB Report No 24/2011, fire on the main vehicle deck of Commodore Clipper, 16 June 2010: CCTV camera 7 hazing from 02:37, sensor D24 alarm at 02:42:36, all camera visibility lost by 02:54; as summarised in RoRoSAFE's Commodore Clipper case study.
  • 2. EMSA, FIRESAFE II (RISE with Bureau Veritas and Stena, December 2018): video and flame detector coverage 'strongly dependent on the position of mounting and if their field of view is blocked by the cargo'.
  • 3. Stowage spacing of about 30 cm bumper to bumper and 10 cm mirror to mirror on car carriers: SAFETY4SEA, 'The carriage, stowage and safety of electric vehicles', as cited in RoRoSAFE's 'What Can Car Park Fires Teach Car Decks?'.
  • 4. IMO Resolution MSC.555(108), FSS Code chapter 9 paragraph 2.5.1.4 (in force 1 January 2026): smoke detection in ro-ro and special category spaces on new ro-pax ships may be disconnected during loading; heat detection and manual call points may not.
  • 5. DNV, 'IMO Sub-Committee on Ship Systems and Equipment (SSE 12)', March 2026: interim guidelines for PCTCs and for video monitoring and detection systems prioritised; correspondence group to SSE 13 in March 2027; SOLAS amendments no earlier than 1 January 2032.
  • 6. MOL press release (November 2023), reported by Maritime Executive and Hellenic Shipping News: Captain's Eye AI cameras on 10 LNG-fuelled car carriers on order, after tests on Onyx Ace detected small amounts of smoke; alerts to crew and shore management.
  • 7. ClassNK (11 October 2024): AFVC(FD)(EV) notation to Positive Challenger (Eastern Car Liner), with AI-camera smoke, heat and rapid temperature-rise detection.
  • 8. 'K' Line, joint R&D agreement with NIPPON HAKUYO electronics and OPT Gate on an optical fire detection system for car carriers, reported by Hellenic Shipping News and World Cargo News.
  • 9. NFPA 72, National Fire Alarm and Signaling Code: video image smoke detection first covered in the 2007 edition; system including software to be listed for smoke detection.
  • 10. Minimum illumination: Bosch AVIOTEC FAQ (2 lux, IR illumination for darker scenes) and Security Sales, 'Video Expands Limits of Fire Detection' (1 foot-candle). Vendor and trade sources.
  • 11. Smoke-detection model performance: International Arab Journal of Information Technology 19(4), 2022, Faster R-CNN with negative-sample mining, 5.76% false-positive rate; Engineering Proceedings (MDPI) 62(1):7 on steam, fog and lighting false alarms; Applied Sciences (2025) review on false alarms and generalisation.
  • 12. Fire Safety Science 8 (IAFSS, 2005): fusion of image processing with temperature and humidity eliminated false alarms from condensed moisture and dust.
  • 13. White pre-ignition vent cloud of gas, particles and aerosolised electrolyte: RSC Energy Advances (2023), d2ya00279e.
  • 14. Electrolyte solvent vapour density (DMC, EMC, DEC about 3.1–4.1 times air): RoRoSAFE, 'Does a Battery Vent Plume Reach the Ceiling?'.
Frequently asked

Questions, answered

Can AI cameras detect a car deck fire earlier than smoke detectors?+

Sometimes. A camera watches a whole lane, so it can register haze before smoke reaches a deckhead detector: on Commodore Clipper in 2010 the deck CCTV hazed about five and a half minutes before the first alarm. It only works where the camera has a clear, lit view, and no published ship trial yet gives head-to-head detection times.

Why do video smoke detectors give false alarms on vehicle decks?+

Because exhaust haze, condensation fog and steam scatter light in the same way smoke does. The FSS Code already lets ro-pax ships switch off smoke detection during loading for this reason. A camera sees the same haze, and models trained on general image sets name steam, fog and lighting changes as their most common false triggers.

Does SOLAS accept video smoke detection as the fixed fire detection system?+

Not today. SOLAS 2026 requires video monitoring on new ro-pax vehicle decks to show what is happening, and fixed detection remains smoke and heat detectors. IMO's SSE 12 prioritised interim guidelines for video monitoring and detection systems in March 2026, and any resulting SOLAS amendments would not enter force before 1 January 2032.

What should an owner test before buying an AI fire camera system?+

Test it on a loaded deck, not a demo bay. Map each camera's view against a full stowage plan and count the bays it cannot see. Confirm the lighting at sea meets the vendor's detection minimum. Log false alarms through loading, humid port calls and open ramp doors, and check whether visual alarms are cross-checked against a second sensor.

Related reading

Continue the thread

RegulationDetection
Sep 16, 2026 · 7 min read

What Does SOLAS 2026 Video Monitoring Require?

Cameras over every passenger-ship vehicle deck, 7-day playback, each camera mapped to a drencher section, no one required to watch. Cargo ships: nothing.

By Vignesh DuraiRead
DetectionRegulation
Sep 24, 2026 · 6 min read

Fire Detection vs Video Monitoring on Ro-Ro Ships

Fire detection raises the alarm; video monitoring shows what raised it. SOLAS 2026 asks new ro-pax ships for both, and neither can stand in for the other.

By Vignesh DuraiRead
ArchitectureSensing
May 2, 2026 · 2 min read

Thermal Cameras vs Thermal Grids at Sea

Both can image temperature. They fail in different places. On a cargo deck the failure modes are what determine the answer.

By Vignesh DuraiRead
SensingDetection
Jun 25, 2026 · Updated Oct 24, 2026 · 4 min read

Aspirating vs Point Smoke on Vehicle Decks

Point detectors alarm only once diluted smoke reaches the deckhead; aspirating (ASD) systems sample air continuously and trip far earlier.

By Vignesh DuraiRead
CasualtyDetection
Sep 22, 2026 · 8 min read

Commodore Clipper: The Alarm Reset 7 Times

A reefer plug ignited on a Condor ro-pax in 2010. Detection worked — 16 sensors, 81 alarms. The crew read a fault, silenced it, and lost 17 minutes.

By Vignesh DuraiRead
SensingDetection
Oct 17, 2026 · 5 min read

Does a Battery Vent Plume Reach the Ceiling?

Often not at first. Early electrolyte vapour is 2–3× denser than air and stays low; only the hot runaway gas rises fast enough for ceiling detectors.

By Vignesh DuraiRead
RegulationClass
Oct 23, 2026 · Updated Nov 25, 2026 · 6 min read

Class Fire Notations Beyond the SOLAS Floor

SOLAS is the floor. ClassNK's AFVC, KR's AFP-C(EV), DNV's EV qualifier and LR's new FIRE (EV) mark fire safety above it. How they compare.

By Vignesh DuraiRead